Nanocrystalline core for Current transformer(NC-M) - Cores - Tianjin he knows technology co
Cores首页 > PRODUCT > Cores > Cores >
Nanocrystalline core for Current transformer(NC-M)
Release date: 2017/11/13 Browse times:

 
  1.Features:
 ØHigh Saturate magnetic induction BS
 ØHigh initial permeability,High linearity, High Accuracy,Low phase and amplitude error for CT 
    ØGood temperature stability(-55℃~130℃)
 ØApplying for transformer class grade: 0.5-0.05 Class

  2. Applications:
 ØHigh precision current and voltage transformer
 ØCurrent leakage circuit breakers
 ØElectronic Watt hour meter
 ØPrecision power meter
 ØCurrent control in automation industry

  3. Specification:
  3-1 Basic parameter

 

Basic magnetic parameter

Nan-crystalline FUI-I

Permalloy(Ni80Fe)

Saturate magnetic induction BS (T)

1.20

0.70

Initial permeability(GS/Oe)

50000~100000

50000~100000

Maximum permeability(GS/Oe)

>300000

>200000

Coercivity(A/m)

<1.6

<0.8

Density(g/cm3)

7.2

8.8

 

  3-2 Typical magnetization curve

  4.Specification and electric parameter

 

Part No.

Core dimensions(mm) 
OD×ID×H

Finished dimensions(mm) 
OD×ID×H

Cross section
AFe
(cm2)

Mean path length
(cm)

Output Voltage(mV)

NC-M 131005

13×9.5×5

14.4×8.2×6.7

0.065

3.5

≥0.1

NC-M 131010

13.2×9.6×10

15×8.5×12.0

0.14

3.58

≥0.30

NC-M 171308

17×13×6.5

20×11.2×9.3

0.097

4.7

≥0.15

NC-M 181305

17.8×13×5

19.6×11.5×6.3

0.09

4.8

≥0.1

NC-M 191207

19×12×6.5

21.1×10.5×8.1

0.17

4.8

≥0.25

NC-M 191407

19×14×6.5

22.1×12.0×9.0

0.12

5.2

≥0.12

NC-M 191408

19×14×8

22.5×12.1×10.1

0.15

5.2

≥0.18

NC-M 191305

18.5×13×5

21.1×11.1×7.2

0.103

4.9

≥0.1

NC-M 201405

20×14×5

22.7×12.4×6.7

0.11

5.3

≥0.1

NC-M 201410

20×14×10

22.5×12.1×12.2

0.23

5.3

≥0.25

NC-M 211510

21×15×10

23.5×12.9×12.8

0.23

5.7

≥0.28

NC-M 211610

21×16×10

24.5×14×12.5

0.19

5.8

≥0.25

NC-M 231608

23×16×8

24.9×14.0×10.9

0.21

6.1

≥0.20

NC-M 261610

26×16×10

28.1×14.0×13.0

0.38

6.6

≥0.30

NC-M 252007

25×20×6.5

27.4×18.2×9.4

0.12

7.1

≥0.07

NC-M 281815

28×18×15

29.5×16.2×17.0

0.57

7.2

   ≥0.32

NC-M 302015

30×20×15

33.1×17.8×17.5

0.57

7.9

≥0.3

NC-M 322010

32×20×10

34.2×18×13.1

0.46

8.2

≥0.22

NC-M 402510

40×25×10

42.5×22.5×13.0

0.57

10.2

≥0.2

NC-M 402515

40×25×15

43.2×21.9×18.9

0.86

10.2

≥0.3

NC-M 503215

50×32×15

53.2×29.0×18.2

1.03

12.9

≥0.23

NC-M 503220

50×32×20

53.2×28.5×23.5

1.37

12.9

≥0.3

NC-M 604020

60×40×20

63×37×24

1.52

15.7

≥0.2

NC-M 644020

64×40×20

67×37×24

1.82

16.3

≥0.22

 

 Note: Testing condition: input 10mA To the specification in the form, cores can be made for meeting user's need.